PLCW-1000 SERIES 2 1/2” x 7”

Product: PLCW-1000 as manufactured by PRL Glass Systems, Inc.

  • Manufacturer Qualifications: Minimum 5 year experience manufacturing similar products.
  • Installer Qualifications: Minimum 2 year experience installing similar products.
  • Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
  • Finish areas designated by Architect.
  • Do not proceed with remaining work until workmanship is approved by Architect.
  • Refinish mock-up area as required to produce acceptable work.

READ MORE

  • Material: Frames, assembly clips, trims and miscellaneous extrusions shall be extruded from Aluminum 6063-T6 alloy.
  • Glazing Gaskets:
  • Class II color anodized aluminum shall:
    1. Color: Champagne.
    2. Color: Light
    3. Color: Medium
    4. Color: Dark
    5. Color: Black
  • Structural silicone compatible gasket: true silicone gasket -70 Durometer Shore "A", complying with ASTM C1115, Type C.
  • Thermal isolators: extruded rigid Geon complying with AAMA-303 and ASTM-D-1784-9.
  • End Dams: Pre-molded end dams made from closed cell EPDM (Ethylene Propylene Diene Monomer) sponge to ASTM C509.

Learn more information about our contfiguration Max Cabo Bipass System

by clicking here.

1.1 REFERENCES
A. American Architectural Manufacturers Association (AAMA):
    1. 1. AAMA/NWWDA 101/I.S. 2-97 – Voluntary Specification, Performance Requirements and Test Procedures for Air Leakage Resistance, Water Penetration Resistance, Structural Loading, Forced Entry Resistance.
    1. 2. AAMA-501.1 – Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure.
    1. 3. AAMA 501.4 – Recommended Static Test Method for Evaluating Curtain Wall and Storefront Systems Subjected to Seismic and Wind Induced Interstory Drifts.
    1. 4. AAMA 2605 – Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels.
B. ASTM International (ASTM):
    1. 1. ASTM B 221 – Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.
    1. 2. ASTM E 283 – Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen.
    1. 3. ASTM E330 – Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference.
    1. 4. ASTM E 331 – Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference.
  1.  

These installation instructions are generic in nature but specific to the PRL curtain wall systems. They are specific to all of PRL’s curtainwalls including the PLCW-600, PLCW-700 and PLCW-1000. Because each project will have differing conditions, each project should have job specific drawings prepared by journeymen drafters or engineers who are familiar with curtain-wall construction and have an intimate understanding of PRL’s curtain wall system and how to integrate it into the construction details specific to the project it is being used on. The shop drawings will take precedence over these instructions as they are project specific. You may refer to PRL’s test reports for further familiarity with construction details of the curtain walls. When in doubt contact your PRL technical representative.

PROJECT NAME   cwl00l         PROJECT NUMBER=1

  • NEUTRAL MOMENT OF 4 36.5477
  • NEUTRAL MOMENT OF INERTIA = B92S3
  • NEUTRAL MOMENT OF INERTIA = .000000
  • POLAR MOMENT OF INERTIA =  4402
  • MAXIMUS MOMENT OF INERTIA = 5477
  • MINIMUM MOMENT OF INERTIA = 89253
  • PRINCIPLE IO LOCAL ANGLE = . OOOOOO

AREf\            3 . 3577 9

PER I METER =        25 . 78 6 7

 

Rmax

– MAXIMUM RADIUS OF GYRATION=

3.29916

Rmin

– MINIMUM RADIUS OF GYRATION-

.928137

 

IXX

 

– GLOBAL

 

MOMENT OF INERTIA

 

 

124.718

IYY

– GLOBAL

MOMENT OF INERTIA

=

8.13910

IXY

– GLOBAL

MOMENT OF INERTIA

=

21.5079

IP

XCG

– GLOBAL POLAR MOM. OF INER.=

— X –  CENT ER O F GRAVI TY

132.857

1 . 2 ‘5 0 0 0

YCG

– Y- CENTER OF GRAVITY

5.12430

AXX

– GLOBAL AREA MOMENT ABOUT-X=

17.2063

AYY

– GLOBAL AREA MOMENT ABOUT-Y=

4.19724

Materials And Finishes

Glass Thickness Color:

Avilable finishes aluminum shall conform:

  1. Air infiltration: Limit air leakage through fixed glazing and frames to 026 cfm/ft2/min (0.01 L/s/m2) when tested in accordance with ASTM E-283-04 at a cross pressure of 6.24 psf (0.30 kPa).
  2. Water Penetration under Static Pressure: System shall not evidence uncontrolled water penetration at a cross pressure of 15 psf (103 kPa) when tested in accordance with ASTM-E331-00.
  3. Water Penetration under Dynamic Pressure: System shall not evidence uncontrolled water penetration at a cross pressure of 15 psf (103 kPa) when tested in accordance with AAMA-501.1-05.

EXPLORE ALL THE PRODUCTS

Love The Results

Discover our entire product gallery by clicking here

PRL Glass  Systems Inc
13644 Nelson Ave, Industry, CA. 91746
251 Mason Way, Industry, CA. 91746

PRL Aluminum Inc
14760 Don Julian rd, Industry, Ca. 91746

Oppening Hours